$41.96
H-File (Ni-Ti) 31 mm 0.45 to 0.80 Assorted Set (6 pack)
$41.96

The Story

H-File (Ni-Ti) 31 mm 0.45 to 0.80 Assorted Set (6 pack)
  • iM3 Control Cut H-File (Ni-Ti) 31 mm 0.45 to 0.80 Assorted Set (6 pack).
  • NiTi H-Files in Assorted Set.
  • Made from Nickel Titanium for increased strength and unique flexibility when working in curved root canals.
  • 31 mm overall length - 16 mm working length.
  • ISO Sizes 0.45, 0.50, 0.55, 0.60, 0.70, and 0.80.
  • 1 of each in an assorted pack of 6 (also available in individual 6 packs).

H-Files or Hedstrom Files, are used in a reciprocating movement to file and shape the root canal. Files and Reamers are intended to be single use and the cost factored in to each procedure.

Sterilization:

Files must be sterilized before use. ANSI/ADA Specification 28 recommends:

  • Scrub the instruments with soap and warm water
  • Rinse thoroughly with distilled or deionized water
  • Allow to air dry
  • Place instruments, unwrapped, in the autoclave tray
  • Use fresh distilled or deionized water
  • Steam Autoclave at 136°C (+/-2°C) for 20 minutes
  • Recommended file disposal: Place used files in Biohazard Sharps container

Description

H-File (Ni-Ti) 31 mm 0.45 to 0.80 Assorted Set (6 pack)
  • iM3 Control Cut H-File (Ni-Ti) 31 mm 0.45 to 0.80 Assorted Set (6 pack).
  • NiTi H-Files in Assorted Set.
  • Made from Nickel Titanium for increased strength and unique flexibility when working in curved root canals.
  • 31 mm overall length - 16 mm working length.
  • ISO Sizes 0.45, 0.50, 0.55, 0.60, 0.70, and 0.80.
  • 1 of each in an assorted pack of 6 (also available in individual 6 packs).

H-Files or Hedstrom Files, are used in a reciprocating movement to file and shape the root canal. Files and Reamers are intended to be single use and the cost factored in to each procedure.

Sterilization:

Files must be sterilized before use. ANSI/ADA Specification 28 recommends:

  • Scrub the instruments with soap and warm water
  • Rinse thoroughly with distilled or deionized water
  • Allow to air dry
  • Place instruments, unwrapped, in the autoclave tray
  • Use fresh distilled or deionized water
  • Steam Autoclave at 136°C (+/-2°C) for 20 minutes
  • Recommended file disposal: Place used files in Biohazard Sharps container

You may also like

NEW
Thumbnail 1

Transofix™ Transfer Spike

$2.68

NEW
Thumbnail 1

Introcan® Straight PUR IV Catheter - 22g x 25mm (1")

$1.39

NEW
Thumbnail 1Thumbnail 2

Cutimed® Sorbact® Hydroactive B

$133.34

NEW
Thumbnail 1Thumbnail 2

Octopus Triple Extension Set with Bionector®

$14.22

NEW
Thumbnail 1Thumbnail 2

T-Connector with Double Bionector® - Luer Lock

$7.20

NEW
Thumbnail 1Thumbnail 2

Single Extension Set with Bionector®

$4.69

NEW
Thumbnail 1Thumbnail 2

BD Vacutainer® Blood Collection Set

$2.68

NEW
Thumbnail 1Thumbnail 2

Bionector®

$2.56

NEW
Thumbnail 1Thumbnail 2

Bionector® and Bag Spike

$5.59

NEW
Thumbnail 1Thumbnail 2

ActivHeal® PHMB Foam Non-adhesive 10x10cm

$115.69

NEW
Thumbnail 1Thumbnail 2

Perfuvet® single-use spiral tubing

$45.11

NEW
Thumbnail 1

Long Arm Dispenser - For Sterillium® 1L Refills

$187.30