$41.01
Equine H-File (Steel) 40mm 0.30 to 0.90 Set (10 pack)
$41.01

The Story

Equine H-File (Steel) 40mm 0.30 to 0.90 Set (10 pack)
  • Made from steel for high torsional strength and excellent flexibility.
  • 40 mm overall length - 16 mm working length.
  • ISO Sizes 0.30, 0.35, 0.40, 0.45, 0.50, 0.55, 0.60, 0.70, 0.80 and 0.90.
  • Taper 0.02.
  • 1 of each in an assorted pack of 10.

H-Files or Hedstrom Files, are used in a reciprocating movement to file and shape the root canal.

These special 40 mm H-files are the preferred length by many equine dentists as they have increased length compared to 31 mm files but are still short enough to allow access at the back of the mouth.

Files and Reamers are intended to be single use and the cost factored in to each procedure.

Sterilization

Files must be sterilized before use. ANSI/ADA Specification 28 recommends:

  • Scrub the instruments with soap and warm water
  • Rinse thoroughly with distilled or deionized water
  • Allow to air dry
  • Place instruments, unwrapped, in the autoclave tray
  • Use fresh distilled or deionized water
  • Steam Autoclave at 136°C (+/-2°C) for 20 minutes
  • Recommended file disposal: Place used files in Biohazard Sharps container

Description

Equine H-File (Steel) 40mm 0.30 to 0.90 Set (10 pack)
  • Made from steel for high torsional strength and excellent flexibility.
  • 40 mm overall length - 16 mm working length.
  • ISO Sizes 0.30, 0.35, 0.40, 0.45, 0.50, 0.55, 0.60, 0.70, 0.80 and 0.90.
  • Taper 0.02.
  • 1 of each in an assorted pack of 10.

H-Files or Hedstrom Files, are used in a reciprocating movement to file and shape the root canal.

These special 40 mm H-files are the preferred length by many equine dentists as they have increased length compared to 31 mm files but are still short enough to allow access at the back of the mouth.

Files and Reamers are intended to be single use and the cost factored in to each procedure.

Sterilization

Files must be sterilized before use. ANSI/ADA Specification 28 recommends:

  • Scrub the instruments with soap and warm water
  • Rinse thoroughly with distilled or deionized water
  • Allow to air dry
  • Place instruments, unwrapped, in the autoclave tray
  • Use fresh distilled or deionized water
  • Steam Autoclave at 136°C (+/-2°C) for 20 minutes
  • Recommended file disposal: Place used files in Biohazard Sharps container

You may also like

NEW
Thumbnail 1

Transofix™ Transfer Spike

$2.68

NEW
Thumbnail 1

Introcan® Straight PUR IV Catheter - 22g x 25mm (1")

$1.39

NEW
Thumbnail 1Thumbnail 2

Cutimed® Sorbact® Hydroactive B

$133.34

NEW
Thumbnail 1Thumbnail 2

Octopus Triple Extension Set with Bionector®

$14.22

NEW
Thumbnail 1Thumbnail 2

T-Connector with Double Bionector® - Luer Lock

$7.20

NEW
Thumbnail 1Thumbnail 2

Single Extension Set with Bionector®

$4.69

NEW
Thumbnail 1Thumbnail 2

BD Vacutainer® Blood Collection Set

$2.68

NEW
Thumbnail 1Thumbnail 2

Bionector®

$2.56

NEW
Thumbnail 1Thumbnail 2

Bionector® and Bag Spike

$5.59

NEW
Thumbnail 1Thumbnail 2

ActivHeal® PHMB Foam Non-adhesive 10x10cm

$115.69

NEW
Thumbnail 1Thumbnail 2

Perfuvet® single-use spiral tubing

$45.11

NEW
Thumbnail 1

Long Arm Dispenser - For Sterillium® 1L Refills

$187.30